SP2/E

vakuVIP with all-round EPS

Data sheet

Structure

Description

  • A 25 mm wide EPS edging strip running around all four sides
  • Holes may be drilled and screws fitted within the area of the edge banding
  • Easy to work with thanks to bonding with standard polystyrene adhesives
  • Easy further finishing of the surface, e.g. by applying plaster mesh and plaster

Top layers

  • Laminated with 10 mm EPS on both the top and bottom surfaces for enhanced mechanical protection
  • A 25 mm wide EPS edge banding running all the way round the four sides
  • Drilling and screw fixing are permitted within the area of the edge banding

Edge formation

  • Flat (straight-edged, at right angles, without profiling)

Insulation core

  • Vacuum insulation panel (vakuVIP B2)
  • Components: Compressed mixture of silica, opacifying agent, cellulose fibres
  • Non-combustible; safe from a physiological and building biology perspective

Formats

Standard formats

  • 1000 x 600 mm
  • 1000 x 300 mm
  • 600 x 500 mm

Standard thicknesses

  • 20 mm
  • 25 mm
  • 30 mm
  • 35 mm
  • 40 mm
  • 45 mm
  • 50 mm
  • 55 mm
  • 60 mm
  • 65 mm
  • 70 mm

Personalised options

  • Special sizes and other thicknesses available on request
  • Bespoke production according to customer requirements or based on a laid-out installation plan

Key features

Thermal conductivity

  • ≤ 0.0040 W/(m·K) Initial value before ageing for vakuVIP at an
    internal pressure of < 5 mbar (measured value during testing in accordance with DIN EN 12667)
  • 0.0070 W/(m·K) Design value, including ageing and edge effects, for
    vakuVIP

Compressive strength

  • ≥ 125 kPa in accordance with DIN EN 826

Density

  • Thickness > 20 mm: 180 to max. 210 kg/m³ in accordance with DIN EN 1602
  • Thickness ≤ 20 mm: 180 to max. 250 k/m³ in accordance with DIN EN 1602

Weight

  • approx. 4 kg/m² at a thickness of 20 mm plus a polystyrene panel

Temperature range

  • -50 to +90°C / -58 to +194°F
  • briefly (approx. 30 mins) up to +130°C / 266°F

Service life

  • in dry conditions (relative humidity < 60 per cent) and
    temperatures of 5 °C – 30 °C, up to 50 years depending on the application

Building material class (DE)

  • DIN 4102-1 B2
  • The core of the vacuum element is non-combustible, Class A1

Environment

  • Recyclable core
  • No glass fibres, no toxic substances

Thickness comparison

U-valueW/(m²K) Building boardWLG 0.007*Thickness in mmMineral woolWLG 0.04*Thickness in mmPolystyreneWLG 0.035*Thickness in mmRigid PU foamWLG 0.03*Thickness in mm
0,6530615446
0,324012611094
0,2250182160137
0,1760240210180
0,1370297260223

U-value of the insulation core based on a λ-value of 0.007 W(m*K) and comparative values for other materials.

* Design value (calculated value) of thermal conductivity for vakuVIP B2 20 mm (for 10 mm, WLG 0.008 applies). The specifications for the U-value and thickness take into account the facing layers (on both sides).

Tailor-made advice

Do you have any questions or would you like a personalised consultation?

Please contact our sales team – we’ll be happy to provide you with expert advice tailored to your specific application and find the ideal solution for your project.