B2

vakuVIP without lamination

Data sheet

Structure

Description

  • Vacuum insulation panel (Z-23.11-1851) approved by the DiBt (German Institute for Building Technology) for the application areas DAD, DAA, DZ, DI, DEO, WAB, WAA, WH, WTR and WI in accordance with standard DIN 4108-10, Table 1
  • As ‘vakuVIP EU’, the product holds a European Technical Assessment (ETA)
  • Awarded the ‘Blue Angel’ quality mark
  • Awarded the RAL quality mark by GSH
  • 100% Made in Germany

Top layers

  • A wide variety of options are available in combination with vakuVIP B2 – please see our portfolio

Edge formation

  • Flat (straight edges, right-angled with no profiling)
  • Optionally available with all-round edge protection

Insulation core

  • vakuVIP B2 vacuum insulation panel
  • Components: Compressed mixture of silica, opacifying agent, cellulose fibres
  • Non-combustible; safe in terms of human health and building biology

Formats

Standard formats

  • 1000 x 600 mm
  • 1000 x 300 mm
  • 600 x 500 mm

Standard thicknesses

  • 10 mm
  • 15 mm
  • 20 mm
  • 25 mm
  • 30 mm
  • 35 mm
  • 40 mm
  • 45 mm
  • 50 mm
  • 55 mm
  • 60 mm

Personalised options

  • Special sizes and other thicknesses available on request
  • Bespoke production according to customer requirements or based on a laid-out installation plan

Key features

Thermal conductivity

  • λ Initial value: ≤ 0.0040 W/(m·K)
  • λ Design value including ageing: approx. 0.0070 W/(m·K)

Compressive strength

  • ≥ 125 kPa (at 10 per cent compression)

Density

  • Thickness > 20 mm: 180–210 kg/m³
  • Thickness ≤ 20 mm: 180–250 kg/m³

Weight

  • Approx. 4 kg/m² for a VIP thickness of 20 mm + superstructures

Temperature range

  • Continuous: −50 to +90 °C
  • Short-term: up to +130 °C (approx. 30 mins)

Service life

  • Up to 50 years (in a dry environment, 5–30 °C, <60 % RH)

Building material class (DE)

  • DIN 4102-1 B2
  • The core of the vacuum element is non-combustible, Class A1

Environment

  • Recyclable core
  • No glass fibres, no toxic substances

Thickness comparison

U-valueW/(m²K) GUMWLG 0.007*Thickness in mmMineral woolWLG 0.04*Thickness in mmPolystyreneWLG 0.035*Thickness in mmRigid PU foamWLG 0.03*Thickness in mm
0,8010504438
0,352011410086
0,2330174152130
0,1740235206176
0,1450286250214

U-value of the insulation core based on a λ-value of 0.007 W(m*K) and comparative values for other materials.

* Design value (calculated value) of thermal conductivity for vakuVIP B2 20 mm (for 10 mm, WLG 0.008 applies).

Tailor-made advice

Do you have any questions or would you like a personalised consultation?

Please contact our sales team – we’ll be happy to provide you with expert advice tailored to your specific application and find the ideal solution for your project.