Structure
Top layers
- Lamination on both the top and bottom sides with 5 mm XPS on each side for enhanced mechanical protection
- Optionally available for double-layer use with lamination on one side only
Edge formation
- Flat (straight edges, right-angled without profiling)
- Optionally available with all-round edge protection
Insulation core
- Vacuum insulation panel (vakuVIP B2)
- Components: Compressed mixture of silica, opacifying agent, cellulose fibres
- Non-combustible; safe from a physiological and building biology perspective

Formats
Standard formats
- 1000 x 600 mm
- 1000 x 300 mm
- 600 x 500 mm
Standard thicknesses
- 20 mm
- 25 mm
- 30 mm
- 35 mm
- 40 mm
- 45 mm
- 50 mm
- 55 mm
- 60 mm
- 65 mm
- 70 mm
Personalised options
- Special sizes and other thicknesses available on request
- Bespoke production according to customer requirements or based on a prepared installation plan
- Where only one side is laminated for double-layer applications, the thickness is reduced by 5 mm

Key features
Thermal conductivity
- ≤ 0.0040 W/(m·K) Initial value before ageing for vakuVIP at an
internal pressure of < 5 mbar (measured value during testing in accordance with DIN EN 12667) - 0.0070 W/(m·K) Design value, including ageing and edge effects, for
vakuVIP
Compressive strength
- ≥ 125 kPa in accordance with DIN EN 826
Density
- Thickness > 20 mm: 180 to max. 210 kg/m³ in accordance with DIN EN 1602
- Thickness ≤ 20 mm: 180 to max. 250 k/m³ in accordance with DIN EN 1602
Weight
- approx. 4 kg/m² at a thickness of 20 mm plus XPS lamination
Temperature range
- -50 to +90°C / -58 to +194°F
- briefly (approx. 30 mins) up to +130°C / 266°F
Service life
- in dry conditions (relative humidity < 60 per cent) and
temperatures of 5 °C – 30 °C, up to 50 years depending on the application
Building material class (DE)
- DIN 4102-1 B2
- The core of the vacuum element is non-combustible, Class A1
Environment
- Recyclable core
- No glass fibres, no toxic substances
Thickness comparison
| U-valueW/(m²K) | XPS-2WLG 0.007*Thickness in mm | Mineral woolWLG 0.04*Thickness in mm | PolystyreneWLG 0.035*Thickness in mm | Rigid PU foamWLG 0.03*Thickness in mm |
|---|---|---|---|---|
| 0,56 | 20 | 71 | 62 | 54 |
| 0,31 | 30 | 128 | 112 | 93 |
| 0,21 | 40 | 190 | 165 | 140 |
| 0,16 | 50 | 245 | 215 | 185 |
| 0,13 | 60 | 300 | 260 | 225 |
U-value of the insulation core based on a λ-value of 0.007 W(m*K) and comparative values for other materials.
* Design value (calculated value) of thermal conductivity for vakuVIP B2 20 mm (for 10 mm, WLG 0.008 applies). The specifications for the U-value and thickness take into account the facing layers (on both sides).