XPS

vakuVIP with XPS lamination

Data sheet

Structure

Top layers

  • Lamination on both the top and bottom sides with 5 mm XPS on each side for enhanced mechanical protection
  • Optionally available for double-layer use with lamination on one side only

Edge formation

  • Flat (straight edges, right-angled without profiling)
  • Optionally available with all-round edge protection

Insulation core

  • Vacuum insulation panel (vakuVIP B2)
  • Components: Compressed mixture of silica, opacifying agent, cellulose fibres
  • Non-combustible; safe from a physiological and building biology perspective

Formats

Standard formats

  • 1000 x 600 mm
  • 1000 x 300 mm
  • 600 x 500 mm

Standard thicknesses

  • 20 mm
  • 25 mm
  • 30 mm
  • 35 mm
  • 40 mm
  • 45 mm
  • 50 mm
  • 55 mm
  • 60 mm
  • 65 mm
  • 70 mm

Personalised options

  • Special sizes and other thicknesses available on request
  • Bespoke production according to customer requirements or based on a prepared installation plan
  • Where only one side is laminated for double-layer applications, the thickness is reduced by 5 mm

Key features

Thermal conductivity

  • ≤ 0.0040 W/(m·K) Initial value before ageing for vakuVIP at an
    internal pressure of < 5 mbar (measured value during testing in accordance with DIN EN 12667)
  • 0.0070 W/(m·K) Design value, including ageing and edge effects, for
    vakuVIP

Compressive strength

  • ≥ 125 kPa in accordance with DIN EN 826

Density

  • Thickness > 20 mm: 180 to max. 210 kg/m³ in accordance with DIN EN 1602
  • Thickness ≤ 20 mm: 180 to max. 250 k/m³ in accordance with DIN EN 1602

Weight

  • approx. 4 kg/m² at a thickness of 20 mm plus XPS lamination

Temperature range

  • -50 to +90°C / -58 to +194°F
  • briefly (approx. 30 mins) up to +130°C / 266°F

Service life

  • in dry conditions (relative humidity < 60 per cent) and
    temperatures of 5 °C – 30 °C, up to 50 years depending on the application

Building material class (DE)

  • DIN 4102-1 B2
  • The core of the vacuum element is non-combustible, Class A1

Environment

  • Recyclable core
  • No glass fibres, no toxic substances

Thickness comparison

U-valueW/(m²K) XPS-2WLG 0.007*Thickness in mmMineral woolWLG 0.04*Thickness in mmPolystyreneWLG 0.035*Thickness in mmRigid PU foamWLG 0.03*Thickness in mm
0,5620716254
0,313012811293
0,2140190165140
0,1650245215185
0,1360300260225

U-value of the insulation core based on a λ-value of 0.007 W(m*K) and comparative values for other materials.

* Design value (calculated value) of thermal conductivity for vakuVIP B2 20 mm (for 10 mm, WLG 0.008 applies). The specifications for the U-value and thickness take into account the facing layers (on both sides).

Tailor-made advice

Do you have any questions or would you like a personalised consultation?

Please contact our sales team – we’ll be happy to provide you with expert advice tailored to your specific application and find the ideal solution for your project.