Structure
Description
- Vacuum insulation panel for cylindrical tanks (hot water tanks, buffer tanks, etc.)
- Also available in a Pro version with further improved thermal conductivity
- Also available as a half-shell
- Heat-resistant high-barrier film up to 100°C with minimal permeability to gases and moisture
Top layers
- At the customer’s request, we can fit the product with double-sided adhesive tape or any type of lamination
Edge formation
- Straight edges, at right angles, without profiling
Insulation core
- Components: Compressed mixture of silica, opacifying agent, cellulose fibres
- Non-combustible; safe for human health and environmentally friendly
Formats
Formats
We manufacture to customer specifications from as little as one item
- Dimensions (unfolded) min. (LxWxH): 100x100x6 mm
- Dimensions (unfolded) max. (LxWxH): 2000x1250x30 mm
Standard thicknesses
- 10 mm
- 15 mm
- 20 mm
- 25 mm
- 30 mm
- 35 mm
- 40 mm
- 45 mm
- 50 mm
- 55 mm
- 60 mm
Personalised options
- Special sizes and other thicknesses available on request
- Bespoke production according to customer requirements or based on a laid-out installation plan
Key features
Thermal conductivity
- λ10 value ≤ 0.004 W/(m·K) (measured value during testing in accordance with DIN EN 12667)
- Pro version: λ10 value ≤ 0.0037 W/(m·K) (measured value in accordance with DIN EN 12667)
Compressive strength
- approx. 140 to 180 kPa in accordance with DIN EN 826
Density
- Thickness ≤ 10 mm: 200 to a maximum of 250 kg/m³ in accordance with DIN EN 1602
- Thickness > 10 mm: 180 to a maximum of 210 kg/m³ in accordance with DIN EN 1602
Weight
- approx. 5 kg/m² at a thickness of 20 mm
Temperature range
- -50 to +100°C / -58 to +212°F
for short periods of approx. 30 mins up to +130°C / 266°F
Environment
- Recyclable
- No glass fibres, no toxic substances