Structure
Top layers
- Laminated on both the top and bottom with 1.4 mm non-woven fabric for enhanced mechanical protection
- Optionally available for double-layer use with lamination on one side only
Edge formation
- Flat (straight edges, right-angled without profiling)
- Optionally available with all-round edge protection
Insulation core
- Vacuum insulation panel (vakuVIP B2)
- Components: Compressed mixture of silica, opacifying agent, cellulose fibres
- Non-combustible; safe from a physiological and building biology perspective

Formats
Standard formats
- 1000 x 600 mm
- 1000 x 300 mm
- 600 x 500 mm
Standard thicknesses
- 13 mm
- 18 mm
- 23 mm
- 28 mm
- 33 mm
- 38 mm
- 43 mm
- 48 mm
- 53 mm
- 58 mm
- 63 mm
Personalised options
- Special sizes and other thicknesses available on request
- Customised production according to customer requirements or based on a prepared installation plan
- Where only one side is laminated for double-layer applications, the thickness is reduced by 1.4 mm

Key features
Thermal conductivity
- λ Initial value: ≤ 0.0040 W/(m·K)
- λ Design value including ageing: approx. 0.0070 W/(m·K)
Compressive strength
- ≥ 125 kPa (at 10 per cent compression)
Density
- Thickness > 20 mm: 180–210 kg/m³
- Thickness ≤ 20 mm: 180–250 kg/m³
Weight
- Approx. 4 kg/m² for a VIP thickness of 20 mm + superstructures
Temperature range
- Continuous: −50 to +90 °C
- Short-term: up to +130 °C (approx. 30 mins)
Service life
- Up to 50 years (in a dry environment, 5–30 °C, <60 % RH)
Building material class (DE)
- DIN 4102-1 B2
- The core of the vacuum element is non-combustible, Class A1
Environment
- Recyclable core
- No glass fibres, no toxic substances
Thickness comparison
| U-valueW/(m²K) | PROTEKTWLG 0.007*Thickness in mm | Mineral woolWLG 0.04*Thickness in mm | PolystyreneWLG 0.035*Thickness in mm | Rigid PU foamWLG 0.03*Thickness in mm |
|---|---|---|---|---|
| 0,78 | 13 | 51 | 55 | 38 |
| 0,35 | 23 | 114 | 100 | 86 |
| 0,23 | 33 | 174 | 152 | 130 |
| 0,17 | 43 | 235 | 206 | 176 |
| 0,14 | 53 | 286 | 250 | 214 |
U-value of the insulation core based on a λ-value of 0.007 W(m*K) and comparative values for other materials.
* Design value (calculated value) of thermal conductivity for vakuVIP B2 20 mm (for 10 mm, WLG 0.008 applies). The specifications for the U-value and thickness take into account the facing layers (on both sides).