GUM

vakuVIP with rubber granulate lamination

Data sheet

Structure

Top layers

  • Laminating on both the top and bottom sides with 3 mm rubber granules for enhanced mechanical protection
  • Optionally available for double-layer use with lamination on one side only

Edge formation

  • Flat (straight edges, right-angled without profiling)
  • Optionally available with all-round edge protection

Insulation core

  • Vacuum insulation panel (vakuVIP B2)
  • Components: Compressed mixture of silica, opacifying agent, cellulose fibres
  • Non-combustible; safe from a physiological and building biology perspective

Formats

Standard formats

  • 1000 x 600 mm
  • 1000 x 300 mm
  • 600 x 500 mm

Standard thicknesses

  • 16 mm
  • 21 mm
  • 26 mm
  • 31 mm
  • 36 mm
  • 41 mm
  • 46 mm
  • 51 mm
  • 56 mm
  • 61 mm
  • 66 mm

Personalised options

  • Special sizes and other thicknesses available on request
  • Customised production according to customer requirements or based on a prepared installation plan
  • Where only one side is laminated for double-layer applications, the thickness is reduced by 3 mm

Key features

Thermal conductivity

  • λ Initial value: ≤ 0.0040 W/(m·K)
  • λ Design value including ageing: approx. 0.0070 W/(m·K)

Compressive strength

  • ≥ 125 kPa (at 10 per cent compression)

Density

  • Thickness > 20 mm: 180–210 kg/m³
  • Thickness ≤ 20 mm: 180–250 kg/m³

Weight

  • Approx. 4 kg/m² for a VIP thickness of 20 mm + superstructures

Temperature range

  • Continuous: −50 to +90 °C
  • Short-term: up to +130 °C (approx. 30 mins)

Service life

  • Up to 50 years (in a dry environment, 5–30 °C, <60 % RH)

Building material class (DE)

  • DIN 4102-1 B2
  • The core of the vacuum element is non-combustible, Class A1

Environment

  • Recyclable core
  • No glass fibres, no toxic substances

Thickness comparison

U-valueW/(m²K) GUMWLG 0.007*Thickness in mmMineral woolWLG 0.04*Thickness in mmPolystyreneWLG 0.035*Thickness in mmRigid PU foamWLG 0.03*Thickness in mm
0,7816515538
0,352611410086
0,2336174152130
0,1746235206176
0,1456286250214

U-value of the insulation core based on a λ-value of 0.007 W(m*K) and comparative values for other materials.

* Design value (calculated value) of thermal conductivity for vakuVIP B2 20 mm (for 10 mm, WLG 0.008 applies). The specifications for the U-value and thickness take into account the facing layers (on both sides).

Tailor-made advice

Do you have any questions or would you like a personalised consultation?

Please contact our sales team – we’ll be happy to provide you with expert advice tailored to your specific application and find the ideal solution for your project.